Oops.. Found the problem. I guess I need to use:
Ascend-Data-Filter += "rules...." ..instead of.. Ascend-Data-Filter = "rules...." I've made the change it seems to be working great. Thanks again! Darren Nay - [EMAIL PROTECTED] On Sat, 12 Jan 2002, Darren Nay wrote: > I'm using Ascend-Data-Filters and for some reason only one of the > Attributes is being sent in the reply. > > Sending Access-Accept of id 234 to 1.2.3.4:1026 > Service-Type = Framed-User > Framed-Protocol = PPP > Framed-Compression = Van-Jacobson-TCP-IP > Framed-MTU = 1500 > Idle-Timeout = 1800 > Session-Timeout = 28800 > Ascend-Idle-Limit = 1800 > Ascend-Maximum-Time = 28800 > Ascend-Data-Filter = "ip input forward tcp" > > I know that in Cistron enable to use the Ascend Filters I had to comment > out some lines in the source that checked for duplicate attributes. Is > the solution the same here? If so, which lines, in which file? > - List info/subscribe/unsubscribe? See http://www.freeradius.org/list/users.html