Oops.. Found the problem.  I guess I need to use:

Ascend-Data-Filter += "rules...."
  ..instead of..
Ascend-Data-Filter = "rules...."

I've made the change it seems to be working great.  Thanks again!

Darren Nay - [EMAIL PROTECTED]

On Sat, 12 Jan 2002, Darren Nay wrote:

> I'm using Ascend-Data-Filters and for some reason only one of the
> Attributes is being sent in the reply.
>
> Sending Access-Accept of id 234 to 1.2.3.4:1026
>         Service-Type = Framed-User
>         Framed-Protocol = PPP
>         Framed-Compression = Van-Jacobson-TCP-IP
>         Framed-MTU = 1500
>         Idle-Timeout = 1800
>         Session-Timeout = 28800
>         Ascend-Idle-Limit = 1800
>         Ascend-Maximum-Time = 28800
>         Ascend-Data-Filter = "ip input forward tcp"
>
> I know that in Cistron enable to use the Ascend Filters I had to comment
> out some lines in the source that checked for duplicate attributes.  Is
> the solution the same here?  If so, which lines, in which file?
>


- 
List info/subscribe/unsubscribe? See http://www.freeradius.org/list/users.html

Reply via email to