Alan DeKok wrote:
...

Incoming RADIUS packet did not have correct Message-Authenticator - dropped
message
on the client side.

  Try adding a Message-Authenticator to the reply.  Any value will do,
as it will be re-calculated when the packet is sent.

freeradius now sends a  Message-Authenticator  with value 0x00:

rad_check_password: Auth-Type = Accept, accepting the user
Sending Access-Accept of id 0 to 156.215.207.190 port 58366
       Tunnel-Medium-Type:0 = IEEE-802
       Tunnel-Type:0 = VLAN
       Tunnel-Private-Group-Id:0 = "VL-G-DE-GU14-0001"
       Message-Authenticator <BARE-WORD> 0x00000000000000000000000000000000
Finished request 0
but there seems to be a problem on the other end, as eapol_test shows:

STA 00:00:00:00:00:02: Received RADIUS packet matched with a pending request, round trip time 0.05 sec
RADIUS packet matching with station
could not extract EAP-Message from RADIUS message

EAPOL: startWhen --> 0
EAPOL test timed out
MPPE keys OK: 0  mismatch: 1
FAILURE

freeradius version is 1.1.6

Norbert Wegener
--

----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Norbert Wegener
Siemens AG Siemens IT Solutions and Services
SBS GO GIO NW PSU2
Kruppstr. 16
D-46128 Essen, Germany
Phone : +49 (0) 201 816-3116
Fax.  : +49 (0) 201 816-5581284
mailto:[EMAIL PROTECTED]


Siemens Aktiengesellschaft: Vorsitzender des Aufsichtsrats: Gerhard Cromme
Vorstand: Peter Löscher, Vorsitzender; Johannes Feldmayer, Heinrich Hiesinger, 
Joe Kaeser, Rudi Lamprecht, Eduardo Montes, Jürgen Radomski, Erich R. 
Reinhardt, Hermann Requardt, Uriel J. Sharef, Klaus Wucherer
Sitz der Gesellschaft: Berlin und München; Registergericht: Berlin 
Charlottenburg, HRB 12300, München, HRB 6684 WEEE-Reg.-Nr. DE 23691322


-
List info/subscribe/unsubscribe? See http://www.freeradius.org/list/users.html

Reply via email to