Absolutely no excuse... I should have read about it... Next time I will read 
more carefully.

Anyway everything works now! Thank you very much Alan Dekok!

Difan

-----Original Message-----
From: freeradius-users-bounces+difan.zhao=guest-tek....@lists.freeradius.org 
[mailto:freeradius-users-bounces+difan.zhao=guest-tek....@lists.freeradius.org] 
On Behalf Of Alan DeKok
Sent: November-19-11 1:37 AM
To: FreeRadius users mailing list
Subject: Re: PEAP Inner-tunnel can't match a user in the "users" file with some 
check attributes

Difan Zhao wrote:

> I have an issue that whenever I have check attributes such as 
> NAS-IP-Address or NAS-Port-Type, my PEAP fails…

  Read raddb/eap.conf.  Look for "copy_request_to_tunnel"

> Everything works once I removed *NAS-IP-Address == "10.143.115.14"*.
> However I do need to check against from which switch/NAS the request 
> is coming from… It seems that those attributes are outside of the “tunnel”.
> How can I copy them in the “tunnel” (does this make sense to you guys)??

  Read the configuration files.  This is documented.

  Alan DeKok.
-
List info/subscribe/unsubscribe? See http://www.freeradius.org/list/users.html

-
List info/subscribe/unsubscribe? See http://www.freeradius.org/list/users.html