Absolutely no excuse... I should have read about it... Next time I will read more carefully.
Anyway everything works now! Thank you very much Alan Dekok! Difan -----Original Message----- From: freeradius-users-bounces+difan.zhao=guest-tek....@lists.freeradius.org [mailto:freeradius-users-bounces+difan.zhao=guest-tek....@lists.freeradius.org] On Behalf Of Alan DeKok Sent: November-19-11 1:37 AM To: FreeRadius users mailing list Subject: Re: PEAP Inner-tunnel can't match a user in the "users" file with some check attributes Difan Zhao wrote: > I have an issue that whenever I have check attributes such as > NAS-IP-Address or NAS-Port-Type, my PEAP fails… Read raddb/eap.conf. Look for "copy_request_to_tunnel" > Everything works once I removed *NAS-IP-Address == "10.143.115.14"*. > However I do need to check against from which switch/NAS the request > is coming from… It seems that those attributes are outside of the “tunnel”. > How can I copy them in the “tunnel” (does this make sense to you guys)?? Read the configuration files. This is documented. Alan DeKok. - List info/subscribe/unsubscribe? See http://www.freeradius.org/list/users.html - List info/subscribe/unsubscribe? See http://www.freeradius.org/list/users.html