Hello,

We are getting the following error while processing T1 data acquired
on Philips. The image data looks ok. We have three scans with similar
error. Does anyone have suggestions as to what could be wrong?

Loading pixel data
/usr/pubsw/packages/vxl/1.13.0/src/core/vnl/algo/vnl_qr.txx: vnl_qr<T>::solve()
: matrix is rank-deficient by 2
/usr/pubsw/packages/vxl/1.13.0/src/core/vnl/algo/vnl_qr.txx: vnl_qr<T>::solve()
: matrix is rank-deficient by 2
/usr/pubsw/packages/vxl/1.13.0/src/core/vnl/algo/vnl_qr.txx: vnl_qr<T>::solve()
: matrix is rank-deficient by 2
/usr/pubsw/packages/vxl/1.13.0/src/core/vnl/algo/vnl_qr.txx: vnl_qr<T>::solve()
: matrix is rank-deficient by 2
/usr/pubsw/packages/vxl/1.13.0/src/core/vnl/algo/vnl_qr.txx: vnl_qr<T>::solve()
: matrix is rank-deficient by 2
/usr/pubsw/packages/vxl/1.13.0/src/core/vnl/algo/vnl_qr.txx: vnl_qr<T>::solve()
: matrix is rank-deficient by 2
/usr/pubsw/packages/vxl/1.13.0/src/core/vnl/algo/vnl_qr.txx: vnl_qr<T>::solve()
: matrix is rank-deficient by 2
/usr/pubsw/packages/vxl/1.13.0/src/core/vnl/algo/vnl_qr.txx: vnl_qr<T>::solve()
: matrix is rank-deficient by 2
MRIresample(): error inverting matrix; determinant is nan, matrix is:
TR=0.00, TE=0.00, TI=0.00, flip angle=0.00
i_ras = (-0, -0, 0)
j_ras = (-0, -0, 0)
k_ras = (nan, nan, nan)
Reslicing using trilinear interpolation
-0.000  -0.000   nan   nan;
-0.000  -0.000   nan   nan;
 0.000   0.000   nan   nan;
 0.000   0.000   0.000   1.000;
Linux node159 2.6.18-164.el5 #1 SMP Tue Aug 18 15:51:48 EDT 2009 x86_64 x86_64 x
86_64 GNU/Linux

recon-all -s 0180634_v00_mr exited with ERRORS at Mon Apr  2 12:25:57 CDT 2012
_______________________________________________
Freesurfer mailing list
Freesurfer@nmr.mgh.harvard.edu
https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer


The information in this e-mail is intended only for the person to whom it is
addressed. If you believe this e-mail was sent to you in error and the e-mail
contains patient information, please contact the Partners Compliance HelpLine at
http://www.partners.org/complianceline . If the e-mail was sent to you in error
but does not contain patient information, please contact the sender and properly
dispose of the e-mail.

Reply via email to