You can use mri_convert, like mri_convert lh.thickness --ascii lh.thickness.txt
this will create a text file with a single column, one row for each vertex. You can also use mri_convert lh.thickness --ascii+crsf lh.thickness.txt This will create 5 columns, the first being the column number, then row number, then slice number, then frame number, then thickness value. In this case, the column number will be the vertex number, and the row, slice, and frame will always be 0. On 05/29/2016 12:19 PM, Francesco Cardinale wrote: > Dear Freesurfer experts, > > I would like to make some algebraic operations with scalars, such as > ?h.thickness or sig.mgh. They are referred to the same surface, of course. > > How can I export the thickness values to a spreadsheet? (?h.thickness > 2 table) > > How can I export the significance values to a spreadsheet? (sig.mgh 2 > table) > > All my best > > Cico > > Francesco Cardinale, MD > > Neurosurgeon > "Claudio Munari" Centre for Epilepsy and Parkinson Surgery - Ospedale > Niguarda "Ca' Granda" > Piazza dell'Ospedale Maggiore, 3 - 20162 - Milano - Italia > <x-apple-data-detectors://0/0> > phone 0039 02 64442917 <tel:0039%2002%2064442917> > fax 0039 02 64442868 <tel:0039%2002%2064442868> > e-mail francesco.cardin...@ospedaleniguarda.it > <mailto:francesco.cardin...@ospedaleniguarda.it> > > > > > _______________________________________________ > Freesurfer mailing list > Freesurfer@nmr.mgh.harvard.edu > https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer -- Douglas N. Greve, Ph.D. MGH-NMR Center gr...@nmr.mgh.harvard.edu Phone Number: 617-724-2358 Fax: 617-726-7422 Bugs: surfer.nmr.mgh.harvard.edu/fswiki/BugReporting FileDrop: https://gate.nmr.mgh.harvard.edu/filedrop2 www.nmr.mgh.harvard.edu/facility/filedrop/index.html Outgoing: ftp://surfer.nmr.mgh.harvard.edu/transfer/outgoing/flat/greve/ _______________________________________________ Freesurfer mailing list Freesurfer@nmr.mgh.harvard.edu https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer The information in this e-mail is intended only for the person to whom it is addressed. If you believe this e-mail was sent to you in error and the e-mail contains patient information, please contact the Partners Compliance HelpLine at http://www.partners.org/complianceline . If the e-mail was sent to you in error but does not contain patient information, please contact the sender and properly dispose of the e-mail.