Hi, I'm using ROI masks (spectroscopy voxels) to get cortical thickness values. I'm pretty much following the tutorial online ('VolumeRoiCorticalThickness') as I'm quite new to Freesurfer. It looks like Freesurfer has a maximum of cortical thickness ceiling at 5 mm, and I'm getting that as the maximum cortical thickness for a fair number of subject's ROI. I'd really like to hear thoughts on this: if it might be indicative of some error happening and if my mean or range cortical thickness is going to be thrown off by it?
Thanks for your help, Kari _______________________________________________ Freesurfer mailing list Freesurfer@nmr.mgh.harvard.edu https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer The information in this e-mail is intended only for the person to whom it is addressed. If you believe this e-mail was sent to you in error and the e-mail contains patient information, please contact the Partners Compliance HelpLine at http://www.partners.org/complianceline . If the e-mail was sent to you in error but does not contain patient information, please contact the sender and properly dispose of the e-mail.