mri_coreg is the FS implementation of spm_coreg (spmregister) both of
which use normalized mutual info. bbregister uses the BBR cost function
and is preferred for all MRI. For registration to MNI space, we usually
use mni152reg (a wrapper around fsl's flirt)
On 2/25/17 8:49 AM, John Anderson wrote:
Dear Freesurfer experts,
I see that the tool "mri_coreg" has been implemented recently in Free
Surfer 6 and I really wanted to know what are the differences between
the registration tools "bbregister", " spmregister" and "mri_coreg"!
Kindly:
1. Are these tools similar? if not what are the differences ?
2. Is there any preference of using a tool over the others for
specific type of data. For example:
A. If I want to register FA map to T1 image which tool is
more robust?
B. if I want to register FA map to MNI space which tool is
more robust?
I highly appreciate your input on this!
John