Hi Mike,

You might want to try putting them in different profiles (maybe one on
port 5080, one on 5082?) so that the provider sees them as coming from
distinct places - that way they should let you use both at once, rather
than just seeing whichever was the last to register.

Cheers --

Dave

> Here they are, mildly modified:
> 
> ~/conf/sip_profiles/external/gateway1212.xml (name changed):
> 
> <include>
>   <gateway name="33.44.55.66">
>         <param name="username" value="8158381212"/>
>         <param name="password" value="bloodyblahbloodyblah"/>
>         <param name="expire-seconds" value="60"/>>
>         <!--/// do not register if value="false"///-->
>         <param name="register" value="true"/>
>         <param name="register-transport" value="udp"/>
>         <param name="retry-seconds" value="30"/>
>         <!--Use the callerid of an inbound call in the from field on
> outbound calls via this gateway -->
>         <param name="caller-id-in-from" value="false"/>
>         <param name="contact-params" value="tport=5060"/>
>         <!--send an options ping every x seconds, failure will
> unregister and/or mark it down-->
>         <param name="ping" value="25"/>
>   </gateway>
> </include>
> 
> ~/conf/sip_profiles/external/gateway1234.xml (name changed for pseudo
> tn):
> 
> <include>
>   <gateway name="33.44.55.66">
>         <param name="username" value="8158381234"/>
>         <param name="password" value="blahbloodyblahblahblah"/>
>         <param name="expire-seconds" value="60"/>>
>         <!--/// do not register if value="false"///-->
>         <param name="register" value="true"/>
>         <param name="register-transport" value="udp"/>
>         <param name="retry-seconds" value="30"/>
>         <!--Use the callerid of an inbound call in the from field on
> outbound calls via this gateway -->
>         <param name="caller-id-in-from" value="false"/>
>         <param name="contact-params" value="tport=5060"/>
>         <!--send an options ping every x seconds, failure will
> unregister and/or mark it down-->
>         <param name="ping" value="25"/>
>   </gateway>
> </include>
> 
> The gateway name is the same for both. Note that each registers and
> passes calls both ways on their own. I'd like to use 'em at the same
> time. 
> 
> Thanks for having a look.
> 
> Mike G.
> 
> On Tue, Sep 29, 2009 at 11:21 AM, Frank Carmickle
> <fr...@carmickle.com> wrote:
>         On Tue, Sep 29, Michael Gende wrote:
>         > Say, could someone please direct me to information on
>         registering more than
>         > one DID with a SIP provider?
>         >
>         > When I try this using two XML files in
>         ~/conf/sip_profiles/external, I find
>         > only one or the other registers (both work fine when I use
>         them separately).
>         
>         
>         Please post your configs with out passwords.  Thanks.
>         
>         --FC
>           
> 
> _______________________________________________
> FreeSWITCH-users mailing list
> FreeSWITCH-users@lists.freeswitch.org
> http://lists.freeswitch.org/mailman/listinfo/freeswitch-users
> UNSUBSCRIBE:http://lists.freeswitch.org/mailman/options/freeswitch-users
> http://www.freeswitch.org
-- 
David Knell, Director, 3C Limited
T: +44 20 3298 2000
E: d...@3c.co.uk
W: http://www.3c.co.uk


_______________________________________________
FreeSWITCH-users mailing list
FreeSWITCH-users@lists.freeswitch.org
http://lists.freeswitch.org/mailman/listinfo/freeswitch-users
UNSUBSCRIBE:http://lists.freeswitch.org/mailman/options/freeswitch-users
http://www.freeswitch.org

Reply via email to