There was just a bunch of work on UPDATE, can you confirm this is the same behavior with trunk?
On Oct 14, 2009, at 6:55 AM, Peter P GMX wrote: > Hello, > > we have the following problem. > 2 Fax machines are communicating via Freeswitch. One is externally > attached via a Telco who is able to handle T.38. The other one is > attached locally. > > When 2 Fax machines start syncing each other, the Telco sends a SIP > UPDATE message with T.38 SDP, as it detects fax during the fax > negociations. > Freeswitch answers with an SIP OK message back to the telco, and I can > see the T.38 SDP on the debug console of freeswitch. > Then nothing happens any more until one of fax machines detects > timeout. > > We have set proxy-media to true. However is was done during call setup > when both machines communicated with G711 SDP. > The UPDATE message was commited by FS to the telco, but was not sent > to > the other fax, so I think in this case Freeswitch is supposed to > transcode between T.38 and G711 which it cannot do, as we know. > > How can I overcome this scenario? Is this a defect, should freeswitch > send the UPDATE message to the other fax? Or is there a workaround? > > Best regards > Peter _______________________________________________ FreeSWITCH-users mailing list FreeSWITCH-users@lists.freeswitch.org http://lists.freeswitch.org/mailman/listinfo/freeswitch-users UNSUBSCRIBE:http://lists.freeswitch.org/mailman/options/freeswitch-users http://www.freeswitch.org