I have just replaced 2 IP 390's running IPSO 4.2/r60 with 2 new IP 395's running IPSO 6.2 bu39/R71, I am seeing a lot of interface input interface errors on all interfaces except for the sync(xover), I have 3 other active interfaces all showing errors, (rxerror, crcerror are the most with a few length and alignment errors), 2 interfaces are connected to an enterasys switch and the 3rd to a cisco. CP recommended that we increase the Rx and Tx ring size to 256, which we did but still see errors but not as many as before, we were seeing 10 of thousands within a 30 minute period before the Tx and Rx ring change, now we are down to 15K for the last 8 hrs. Is anyone else on this IP model and versions seeing any issues with this? Thanks,
================================================= To set vacation, Out-Of-Office, or away messages, send an email to [email protected] in the BODY of the email add: set fw-1-mailinglist nomail ================================================= To unsubscribe from this mailing list, please see the instructions at http://www.checkpoint.com/services/mailing.html ================================================= If you have any questions on how to change your subscription options, email [email protected] =================================================