I've run into this before as well.  I've had to putkey the machines again to
get it to work.  For some reason, the putkeys seem to go to lunch sometimes.

As far as the No such file error, I recently ran into this problem when I
had a Time object with a name longer than 11 characters.  After I changed it
to a shorter name, the error went away and the policy load worked fine.
Strange thing about this was that the policy load worked a couple of times
w/ the name > 11 characters and then stopped working and wouldn't work until
the rename.

Kevin


-----Original Message-----
From: Simon Guo [mailto:[EMAIL PROTECTED]]
Sent: Wednesday, August 02, 2000 10:56 AM
To: '[EMAIL PROTECTED]'
Subject: [FW1] Provider-1



Hi,

I have a CMA manages 4 firewalls. Two of them are fine while other two
cannot install policy. The message:Resouce temporarily unavailable'.


I checked the fwd.log of the two firewall module. One said
fwd: Log Server 219.231.138.110 went down

The other said:
fwd: mdq_run: exec(/opt/fw1/bin/mdq): No such file or directory

What's going wrong?

Thanks for helps.