I am having a problem with my (2) Nokias. I have gone through an configured VRRP (monitored circuits) on all the interfaces on both of the boxes. All seem to be working properly except on 1 interface. The interface in question is problematic since both the primary and secondary are arp'ing for the VRRP MAC. I checked all the settings on the Nokias (Priority, priority delta, hello interval, VRID) and they are all correct. When I look at ICLID and do a 'sh vrrp stats' command on the primary that their are 6 interfaces in Master mode and 0 in backup mode. However on the backup it indicates that 5 are in backup and 1 in master. On the Voyager GUI under monitor, VRRP, interfaces the backup indicates that the effective and base priorities are at 95, but in a Master state. The primary effective and base priorities indicate 100 and again Master state. The only thing different about this interface is that it has a secondary address which is not configured for VRRP, but that should not matter, correct Any ideas on what is happening??? Thanks, Nishith Kamdar mailto:[EMAIL PROTECTED] ================================================================================ To unsubscribe from this mailing list, please see the instructions at http://www.checkpoint.com/services/mailing.html ================================================================================