On vendredi 03 octobre 2008, Gaël Le Hec'H wrote: > Hi, > I need to receive data from a device with serial port with 19200 bauds 8 > bits data Even parity 2 stop bits settings, but I get only 7 bits of my > data. > I check with serlook and data received is correct : 10 00 00 F0, with > gambas I receive 10 00 00 70 > I check the change log of the component but didn't see any problem with > parity setting. > I use version 2.0.0 of gambas2 (I know it's old but with my slackware 11 I > can't get newer version to compile). > It 's a very annoying problem because I can't change the serial settings of > my device :-( > kind regards > > Gaël
I fixed that I have fixed the problem in revision #1624, and it would be cool if you could compile the latest version of Gambas to check that. Why can't you compile a recent version of Gambas on slackware 11? -- Benoit Minisini ------------------------------------------------------------------------- This SF.Net email is sponsored by the Moblin Your Move Developer's challenge Build the coolest Linux based applications with Moblin SDK & win great prizes Grand prize is a trip for two to an Open Source event anywhere in the world http://moblin-contest.org/redirect.php?banner_id=100&url=/ _______________________________________________ Gambas-user mailing list Gambas-user@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/gambas-user