On Mon, May 30, 2011 at 01:07:22PM +0200, Michael Hanselmann wrote:
> This fixes a unittest failure on 32 bit systems. A recently added
> unittest for ht.TJobId uses a rather large number (2347625220). On 64
> bit systems it is stored as “int”. On 32 bit systems however, Python
> uses “long”. The two types can be intermixed in Python as the
> interpreter will take care of conversions. If one processed too many
> jobs (2**31) on a 32 bit system, ht would no longer accept the job IDs.

LGTM.