Comment #6 on issue 229 by [email protected]: Ganeti fails to rollback on a failed disk conversion (plain -> DRBD)
http://code.google.com/p/ganeti/issues/detail?id=229

commit f38270c6da11811d432db51061a32d3b85823372
Author: Klaus Aehlig <[email protected]>
Date:   Tue Apr 23 11:35:18 2013 +0200

    In plain to drbd conversion, rename LVs back on failure

    Currently, if converting an instance from plain to drbd fails after
    renaming the original LVs, the instance is left in an inconsistent
    state. This commit tries to undo the renaming if a failure occurs
    on assembling a DRBD device, e.g., when device minor numbers are
    exhausted. (Issue 229)

    Signed-off-by: Klaus Aehlig <[email protected]>
    Reviewed-by: Thomas Thrainer <[email protected]>


--