The user shutdown parameter was being enabled for the instance before the test starts but afterwards it was not being disabled.
Signed-off-by: Jose A. Lopes <[email protected]> --- qa/qa_instance.py | 3 +++ 1 file changed, 3 insertions(+) diff --git a/qa/qa_instance.py b/qa/qa_instance.py index e2456db..6d86286 100644 --- a/qa/qa_instance.py +++ b/qa/qa_instance.py @@ -1253,6 +1253,9 @@ def _TestInstanceUserDownKvm(instance): primary = _GetInstanceField(instance.name, "pnode") _TestInstanceUserDown(instance, _StopKVMInstance) + AssertCommand(["gnt-instance", "modify", "-H", "user_shutdown=false", + instance.name]) + def TestInstanceUserDown(instance): """Tests user shutdown""" -- 2.0.0.526.g5318336