Default consolidation function for values is average. Default polling period is 15 seconds so if you are viewing more than an hour you likely will have more data points than can fit on the graph so things will start being averaged.

On Wed, 30 May 2012, Vitthal "Suhas" Gogate wrote:

Any one has any insight? Really appreciate!  Thanks & Regards, Suhas

On Fri, May 25, 2012 at 4:56 PM, Vitthal "Suhas" Gogate 
<gog...@hortonworks.com> wrote:
      I am looking at total processes graph on one of the nodes and I see value of  
"now"  is fractional (i.e. current number of
      processes are reported in fraction).  This metric is Guage type (as I see 
it in the rrd file) and I don't see why fractional
      number would be reported ever for the total processes..

      So according to my knowledge the gauge metric is plotted as it is..  am I 
missing?   Is this metric averaged over time? Why I
      see the fractional value?

      Any insight would really be helpful..  Thanks in advance!

      --Suhas



------------------------------------------------------------------------------
Live Security Virtual Conference
Exclusive live event will cover all the ways today's security and 
threat landscape has changed and how IT managers can respond. Discussions 
will include endpoint security, mobile security and the latest in malware 
threats. http://www.accelacomm.com/jaw/sfrnl04242012/114/50122263/
_______________________________________________
Ganglia-general mailing list
Ganglia-general@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/ganglia-general

Reply via email to