------- Comment #19 from ian at airs dot com 2007-07-02 02:50 ------- I don't see an inconsistency in my answers. If you mark local variables as having a reference to the stack pointer before combine, then you should handle log_links as appropriate.
I am explicitly not telling you what to do. I am telling you what the problem is, and leaving the solution up to you. The correct solution is in the dataflow code, which I don't really know. -- http://gcc.gnu.org/bugzilla/show_bug.cgi?id=32475