------- Comment #19 from ian at airs dot com  2007-07-02 02:50 -------
I don't see an inconsistency in my answers.  If you mark local variables as
having a reference to the stack pointer before combine, then you should handle
log_links as appropriate.

I am explicitly not telling you what to do.  I am telling you what the problem
is, and leaving the solution up to you.  The correct solution is in the
dataflow code, which I don't really know.


-- 


http://gcc.gnu.org/bugzilla/show_bug.cgi?id=32475