Steve Meier wrote:
IPC-2511B is the xml version of GENCAM. unfortunately, 2511B39.xsd is the latest version of the schema and it has 34 errors when verified by the w3c schema verifier atEDA File Formats
GENCAM Generic Computer Aided Manufacturing
Satndard: IPC-2511
http://www.w3.org/2001/03/webdata/xsv. if 2511B39.xsd were valid and, therefore, had meaning, it could be used to represent schematics, non-hierarchical netlists and pcbs.
IPC-2581 is an xml standard that is valid and can be used to represent non-hierarchical netlists and pcbs.
some IPC standards including IPC-2511B and IPC-2581 are available from http://webstds.ipc.org/25XXmatrix.htm