On Sat, Sep 11, 2010 at 08:57:21PM -0400, Bob Paddock wrote: > > How about a keep-out layer with a layer enable list? "This keep-out > applies to layers 1,2,4,7,8", and a "This keep-out applies to all > layers". > Realistically I've wanted to 'keep-out' Top Layer, Bottom Layer, or All > Layers in almost all cases. >
In the spirit of treating all layers the same, perhaps this should be a feature for all layers? That is, allowing each pcb layer to map to any number of physical layers. This would replace the current layer group functionality, but be much more flexible and elegant. Andrew _______________________________________________ geda-user mailing list geda-user@moria.seul.org http://www.seul.org/cgi-bin/mailman/listinfo/geda-user