Bob Paddock wrote:

>> This is a DRC issue. The rules should allow any net to connect
>> to no-net copper. No need to restructure the way pcb handles
>> connectivity.
> 
> If different nets connect to the same no-net copper there is a short
> between nets.

Of course, connectivity needs to be recalculated (automatically)
after a net has been connected to a no-net. As a consequence, the
no-net copper will have been converted to what ever net it was 
connected to.

---<)kaimartin(>---
-- 
Kai-Martin Knaak
Öffentlicher PGP-Schlüssel: