Thanks for the quick replies.
Adding the Text line fixed the schem message. Still having
problems with PCB not detecting the net criss-cross when I
intentionally miss-connect the nets. PCB is indicates a RAT
between the Power and Ground.
George
On 02/17/2011 09:54 AM, John Doty wrote:
On Feb 17, 2011, at 6:57 AM, George M. Gallant, Jr. wrote:
I have created a symbol for the TI ADS1298. It has multiple power pins,
DVdd, DVss, ADvv,& AVss. For test purposes, I declared 1 of the pins as
a net.
Loadiing the schematic gives:
Read garbage in [ads1298-1.sym] :
net=AVdd:21
<<
I'm guessing you added that line to the symbol with a text editor. It needs to
be a part of a text object. Adding it with gschem avoids this problem, or you
could, in a text editor, precede it with something like:
T 0 0 0 0 0 0 0 0 1
John Doty Noqsi Aerospace, Ltd.
http://www.noqsi.com/
j...@noqsi.com
_______________________________________________
geda-user mailing list
geda-user@moria.seul.org
http://www.seul.org/cgi-bin/mailman/listinfo/geda-user
_______________________________________________
geda-user mailing list
geda-user@moria.seul.org
http://www.seul.org/cgi-bin/mailman/listinfo/geda-user