Thanks for the quick replies.

Adding the Text line fixed the schem message. Still having
problems with PCB not detecting the net criss-cross when I
intentionally miss-connect the nets. PCB is indicates a RAT
between the Power and Ground.

George

On 02/17/2011 09:54 AM, John Doty wrote:
On Feb 17, 2011, at 6:57 AM, George M. Gallant, Jr. wrote:

I have created a symbol for the TI ADS1298. It has multiple power pins,
DVdd, DVss, ADvv,&  AVss. For test purposes, I declared 1 of the pins as
a net.

Loadiing the schematic gives:

Read garbage in [ads1298-1.sym] :
net=AVdd:21
<<
I'm guessing you added that line to the symbol with a text editor. It needs to 
be a part of a text object. Adding it with gschem avoids this problem, or you 
could, in a text editor, precede it with something like:

T 0 0 0 0 0 0 0 0 1

John Doty              Noqsi Aerospace, Ltd.
http://www.noqsi.com/
j...@noqsi.com




_______________________________________________
geda-user mailing list
geda-user@moria.seul.org
http://www.seul.org/cgi-bin/mailman/listinfo/geda-user




_______________________________________________
geda-user mailing list
geda-user@moria.seul.org
http://www.seul.org/cgi-bin/mailman/listinfo/geda-user