This is an automatically generated e-mail. To reply, visit:
http://reviews.gem5.org/r/3315/
-----------------------------------------------------------

Review request for Default.


Repository: gem5


Description
-------

Changeset 11331:8492ca5ea301
---------------------------
mem: [DRAFT] Make DRAMCtrl response queue finite

The DRAMCtrl had an effectively infinite response queue by using the
QueuedSlavePort to manage responses. Unfortunately, for high-bandwidth
applications, this queue causes unrealistic bloat, quickly filling with more
than 100 packets.

To fix this issue, change the response port from a QueuedSlavePort back to a
standard SlavePort, and implement the appropriate control flow. This includes
adding a backend queue, in which slots are reserved when packets arrive at on
the DRAMCtrl's request path.


Diffs
-----

  src/mem/dram_ctrl.cc 10647f5d0f7f 
  src/mem/DRAMCtrl.py 10647f5d0f7f 
  src/mem/dram_ctrl.hh 10647f5d0f7f 

Diff: http://reviews.gem5.org/r/3315/diff/


Testing
-------

Tested running with gem5's memtest.py:

../build/X86/gem5.opt --debug-flag=DRAM --outdir=$outdir 
../configs/example/memtest.py -u 100

and a couple hundred varying GPU workloads in gem5-gpu.


Thanks,

Joel Hestness

_______________________________________________
gem5-dev mailing list
[email protected]
http://m5sim.org/mailman/listinfo/gem5-dev

Reply via email to