Hello all
I have incorporated an L3 cache in configs/common/CacheConfig.py as
follows:
if options.l2cache:
system.l2 = l2_cache_class(clock=options.clock,
size=options.l2_size,assoc=options.l2_assoc,
block_size=options.cacheline_size)
system.tol2bus = CoherentBus(clock = options.clock, width = 32)
if options.l3cache:
system.tol3bus = CoherentBus(clock = options.clock, width = 32)
system.l2.cpu_side = system.tol2bus.master
system.l2.mem_side = system.tol3bus.slave
system.l3 = L3Cache(size = options.l3_size, assoc =
options.l3_assoc, block_size=options.cacheline_size)
system.l3.cpu_side = system.tol3bus.master
system.l3.mem_side = system.membus.slave
else:
system.l2.mem_side = system.membus.slave
system.l2.cpu_side = system.tol2bus.master
----------some code which I have not changed------
if options.l2cache and options.l3cache :
system.cpu[i].connectAllPorts(system.tol3bus, system.membus)
elif options.l2cache and not options.l3cache:
system.cpu[i].connectAllPorts(system.tol2bus, system.membus)
else:
system.cpu[i].connectAllPorts(system.membus)
I ran the following commands:
1) ./build/ARM/gem5.opt --debug-flags=DRAM configs/example/se.py -c
queens -o 8 --caches --l2cache --l1d_size=1kB --l1i_size=1kB *--l2_size=2MB*
system.l2.overall_misses::total 591
system.physmem.num_reads::total 591
2) ./build/ARM/gem5.opt --debug-flags=DRAM configs/example/se.py -c queens
-o 8 --caches --l2cache --l1d_size=1kB --l1i_size=1kB *--l2_size=2kB*
system.l2.overall_misses::total 1081
system.physmem.num_reads::total 1081
For these cases, the results seem to be consistent as the overall misses
increases with decreasing L2 size and these go to physmem(which is DRAM in
this case) for further servicing. According to my understanding if I insert
an L3 cache between L2 and Physmem then L2 misses should not change and
should be served by L3.
*Problem 1*) After the incorporation of L3 cache I am not able to see L2
misses ("system.l2.overall_misses::total ") anymore, and only L3 misses are
reported in stats.txt file. How can I see L2 misses?*
Problem2) *Whatever be the size of L2 cache, number of misses at L3 are
constant.
3)./build/ARM/gem5.opt --debug-flags=DRAM configs/example/se.py -c queens
-o 8 --caches --l2cache --l3cache --l1d_size=1kB --l1i_size=1kB *--l2_size=2MB
--l3_size=1MB*
system.physmem.num_reads::total 591
system.l3.overall_misses::total 591
4)./build/ARM/gem5.opt --debug-flags=DRAM configs/example/se.py -c queens
-o 8 --caches --l2cache --l3cache --l1d_size=1kB
--l1i_size=1kB*--l2_size=2kB --l3_size=1MB
*
system.physmem.num_reads::total 591
system.l3.overall_misses::total 591
I would like to see misses occuring at every level of memory hierarchy.
Kindly help me about how to do this.
Best Regards
Shivam Agarwal
Student, IIT-Delhi
_______________________________________________
gem5-users mailing list
[email protected]