Hi Michal! I am inverting a flat surface in order to obtain the geometry of the basement for a given magnetic susceptibility. And the magnetic survey is at 2200 m, so I do not believe I am modelling on a draped surface, unless the top of my model should be a flat surface instead of the topography.
This is very annoying. I can not obtain any meaningful results. But thanks for your help! Best regards, Conxi Michal writes: > Hi Conxi, > > I'm not familiar with an updated tutorial for this process, but - > Do you calculate from a draped surface (grid) or a constant elevation? > If you're modeling on a draped surface, your inversion results might be > incorrect due to a bug. This is an issue I've encountered before and as far > as I know this problem hasn't been resolved yet. > It might be helpful for you to test the same model and the same inversion > process on a constant elevation, and then see whether the results make any > sense. > > Good luck, > Michal > --- > > Forum archives can be accessed here: > http://lyris.geosoft.com/read/?fourm=geonet > You are currently subscribed to geonet as: [email protected]. > To subscribe or unsubscribe from any of our forums, select the User Forum > selection on the Geosoft Community page: > http://www.geosoft.com/support/community ______________________________ Dra. Conxi Ayala IGME Departamento de Investigación y Prospectiva Área de Geología del Subsuelo y Almacenamiento Geológico Geofísica email: [email protected] _______________________ www.igme.es --- Forum archives can be accessed here: http://lyris.geosoft.com/read/?fourm=geonet You are currently subscribed to geonet as: [email protected]. To subscribe or unsubscribe from any of our forums, select the User Forum selection on the Geosoft Community page: http://www.geosoft.com/support/community