Harald Welte has submitted this change and it was merged. Change subject: mgcp: add missing switch case ......................................................................
mgcp: add missing switch case In the beginning of the CRCX phase for the network does not distinguish between EV_MDCX_BTS_RES and EV_TEARDOWN, so a Teardown due to an error could be misinterpreted as a successful MGW response. Add missing case statement to distinguish CV_MDCX_BTS_RES from EV_TEARDOWN. Change-Id: I9bf49df167d94b33ad65d8b9382a01f160b5aec0 --- M src/osmo-bsc/osmo_bsc_mgcp.c 1 file changed, 8 insertions(+), 0 deletions(-) Approvals: Harald Welte: Looks good to me, approved Jenkins Builder: Verified diff --git a/src/osmo-bsc/osmo_bsc_mgcp.c b/src/osmo-bsc/osmo_bsc_mgcp.c index a7d1f94..be6c7de 100644 --- a/src/osmo-bsc/osmo_bsc_mgcp.c +++ b/src/osmo-bsc/osmo_bsc_mgcp.c @@ -456,6 +456,14 @@ "fsm-state: %s, fsm-event: %s\n", get_value_string(fsm_bsc_mgcp_state_names, fi->state), get_value_string(fsm_evt_names, event)); + switch (event) { + case EV_MDCX_BTS_RESP: + break; + default: + handle_error(mgcp_ctx, MGCP_ERR_UNEXP_TEARDOWN); + return; + } + rtp_endpoint = mgcp_ctx->rtp_endpoint; LOGPFSML(mgcp_ctx->fsm, LOGL_DEBUG, -- To view, visit https://gerrit.osmocom.org/4983 To unsubscribe, visit https://gerrit.osmocom.org/settings Gerrit-MessageType: merged Gerrit-Change-Id: I9bf49df167d94b33ad65d8b9382a01f160b5aec0 Gerrit-PatchSet: 4 Gerrit-Project: osmo-bsc Gerrit-Branch: master Gerrit-Owner: dexter <pma...@sysmocom.de> Gerrit-Reviewer: Harald Welte <lafo...@gnumonks.org> Gerrit-Reviewer: Jenkins Builder