Harald Welte has submitted this change and it was merged.

Change subject: mgcp: add missing switch case
......................................................................


mgcp: add missing switch case

In the beginning of the CRCX phase for the network does not distinguish
between EV_MDCX_BTS_RES and EV_TEARDOWN, so a Teardown due to an error
could be misinterpreted as a successful MGW response.

Add missing case statement to distinguish CV_MDCX_BTS_RES from
EV_TEARDOWN.

Change-Id: I9bf49df167d94b33ad65d8b9382a01f160b5aec0
---
M src/osmo-bsc/osmo_bsc_mgcp.c
1 file changed, 8 insertions(+), 0 deletions(-)

Approvals:
  Harald Welte: Looks good to me, approved
  Jenkins Builder: Verified



diff --git a/src/osmo-bsc/osmo_bsc_mgcp.c b/src/osmo-bsc/osmo_bsc_mgcp.c
index a7d1f94..be6c7de 100644
--- a/src/osmo-bsc/osmo_bsc_mgcp.c
+++ b/src/osmo-bsc/osmo_bsc_mgcp.c
@@ -456,6 +456,14 @@
                 "fsm-state: %s, fsm-event: %s\n",
                 get_value_string(fsm_bsc_mgcp_state_names, fi->state), 
get_value_string(fsm_evt_names, event));
 
+       switch (event) {
+       case EV_MDCX_BTS_RESP:
+               break;
+       default:
+               handle_error(mgcp_ctx, MGCP_ERR_UNEXP_TEARDOWN);
+               return;
+       }
+
        rtp_endpoint = mgcp_ctx->rtp_endpoint;
 
        LOGPFSML(mgcp_ctx->fsm, LOGL_DEBUG,

-- 