Attention is currently required from: pespin. dexter has posted comments on this change. ( https://gerrit.osmocom.org/c/osmo-bsc/+/31618 )
Change subject: pcu_sock: handle multiple BTSs with one BSC co-located PCU (in theory) ...................................................................... Patch Set 2: (1 comment) File src/osmo-bsc/pcu_sock.c: https://gerrit.osmocom.org/c/osmo-bsc/+/31618/comment/0548b9c6_6402226f PS1, Line 981: LOGP(DPCU, LOGL_ERROR, "This version of OsmoBSC can only handle one (Ericsson RBS) BTS with BSC co-located PCU\n"); > so what's exactly preventing us from operating multiple ericsson RBS? do we > have a ticket open about […] I am not exactly sure. At least the direct PHY API has no way to distinguish between different BTSs. The PCU has a BTS list. Thats all I know. Fixing the PHY part is probably easy but I do not know if there are other limitations. As far as the BSC is concerned the limitations should be gone. I have created a ticket now: https://osmocom.org/issues/5930 -- To view, visit https://gerrit.osmocom.org/c/osmo-bsc/+/31618 To unsubscribe, or for help writing mail filters, visit https://gerrit.osmocom.org/settings Gerrit-Project: osmo-bsc Gerrit-Branch: master Gerrit-Change-Id: I0b42c2c130106f6ffca2dd08d079e1a7bda41f0b Gerrit-Change-Number: 31618 Gerrit-PatchSet: 2 Gerrit-Owner: dexter <pma...@sysmocom.de> Gerrit-Reviewer: Jenkins Builder Gerrit-CC: pespin <pes...@sysmocom.de> Gerrit-Attention: pespin <pes...@sysmocom.de> Gerrit-Comment-Date: Thu, 02 Mar 2023 09:12:07 +0000 Gerrit-HasComments: Yes Gerrit-Has-Labels: No Comment-In-Reply-To: pespin <pes...@sysmocom.de> Gerrit-MessageType: comment