Attention is currently required from: pespin.

dexter has posted comments on this change. ( 
https://gerrit.osmocom.org/c/osmo-bsc/+/31618 )

Change subject: pcu_sock: handle multiple BTSs with one BSC co-located PCU (in 
theory)
......................................................................


Patch Set 2:

(1 comment)

File src/osmo-bsc/pcu_sock.c:

https://gerrit.osmocom.org/c/osmo-bsc/+/31618/comment/0548b9c6_6402226f
PS1, Line 981:          LOGP(DPCU, LOGL_ERROR, "This version of OsmoBSC can 
only handle one (Ericsson RBS) BTS with BSC co-located PCU\n");
> so what's exactly preventing us from operating multiple ericsson RBS? do we 
> have a ticket open about […]
I am not exactly sure. At least the direct PHY API has no way to distinguish 
between different BTSs. The PCU has a BTS list. Thats all I know. Fixing the 
PHY part is probably easy but I do not know if there are other limitations. As 
far as the BSC is concerned the limitations should be gone. I have created a 
ticket now: https://osmocom.org/issues/5930



--