Attention is currently required from: pespin.

laforge has posted comments on this change by pespin. ( 
https://gerrit.osmocom.org/c/osmo-ttcn3-hacks/+/41426?usp=email )

Change subject: Configure all ttcn-3 SCCP endpoints to match IUT ss7 
network-indicator
......................................................................


Patch Set 2: Code-Review+1

(1 comment)

Patchset:

PS2:
it was intentional that osmocom software uses international by default (as 
that's the only one standardized to use ITU SS7, while "national" can mean many 
different national flavours of SS7 including ANSI, which we never implemented.  
The test suites have been wrong and should be fixed with a patch like this.



--