Harald Welte has uploaded this change for review. ( https://gerrit.osmocom.org/14137
Change subject: sysmo: Fix "nominal power" / BS power display in VTY ...................................................................... sysmo: Fix "nominal power" / BS power display in VTY The function get_p_max_out_mdBm() returns a value in 1/1000th of dBm, "milli-dBm", while trx->nominal_power is only whole dBm. We were missing the required divider of 1000 ever since Change-Id Ieff75d5becaa80a2097b6e744c75c2d16259c9a4 was merged in February 2017. The good news is that this really only affected the VTY output and not any actual operational aspect of the system. Change-Id: If92d0b15c48dafc63776b82c7ff5f3c2b3505f68 Closes: SYS#4570 --- M src/osmo-bts-sysmo/l1_if.c 1 file changed, 1 insertion(+), 1 deletion(-) git pull ssh://gerrit.osmocom.org:29418/osmo-bts refs/changes/37/14137/1 diff --git a/src/osmo-bts-sysmo/l1_if.c b/src/osmo-bts-sysmo/l1_if.c index 87cf25a..6f61c67 100644 --- a/src/osmo-bts-sysmo/l1_if.c +++ b/src/osmo-bts-sysmo/l1_if.c @@ -1883,7 +1883,7 @@ LOGP(DL1C, LOGL_NOTICE, "Cannot determine nominal " "transmit power. Assuming 23dBm.\n"); } - bts->c0->nominal_power = rc; + bts->c0->nominal_power = rc / 1000; } hdl = pinst->u.sysmobts.hdl; -- To view, visit https://gerrit.osmocom.org/14137 To unsubscribe, or for help writing mail filters, visit https://gerrit.osmocom.org/settings Gerrit-Project: osmo-bts Gerrit-Branch: master Gerrit-MessageType: newchange Gerrit-Change-Id: If92d0b15c48dafc63776b82c7ff5f3c2b3505f68 Gerrit-Change-Number: 14137 Gerrit-PatchSet: 1 Gerrit-Owner: Harald Welte <lafo...@gnumonks.org>