Martin LEPSIK wrote:

Dear GROMACS users,

I would like to ask you maybe a trivial question: What is the best way to image a protein with a ligand inside
a triclinic water box?

I run an MD in GMX-3.3 with nstcomm=1, "comm_grps" and "comm_mode" not set. I watch the movie in VMD, loading first a starting gro and than the trr. The problem is that the protein creeps out of the box (the same happens
when using ngmx).

I have tried various variants of post-processing using trjconv -fit (translation) -pbc (inbox, whole) -center (tric), groups for fitting: protein or system. But in any case, the result is the same.

Could you please advice me how to solve this? Whether it is better to include some parameter for
mdrun or to post-process in a different way?

Looking forward to hearing from you.

Yours sincerely,

Martin Lepsik

You can either
use comm_grps = Protein and comm_mode = Linear
or
use trjconv with the -fit option and fit your protein on the starting position after finishing the simulation.

Cheers, Jochen


--
************************************************