On 2/28/2007 7:52 PM, Mark Abraham wrote:
Qiang Zhong wrote:
Dear users:
I want to prepare protein simulation on 0.15mol/l salt concentration,I use genion command to add ions,After genion,I change cln.top file last line to NA+
61,CL- 41.
   When I execute grompp ,there are warning :

Warning: atom names in cln.top and cln_b4em.gro don't match (CL - Na)
........
(more than 20 non-matching atom names)
WARNING 1 [file "cln.top", line 9059]:
  102 non-matching atom names
  atom names from cln.top will be used
  atom names from cln_b4em.gro will be ignored

I continue to execute "mdrun nice 0 -v -s cln_em.tpr -o minim_traj.trr -c
minimized.gro -e minim_ener.edr",There are some error:

Hardly surprising... most gromacs warnings should be considered carefully.
I think what Mark means is that in such case, you shall not continue to run mdrun without inspecting the warnings.
First the atom names in your .gro and .top files have to match those in the .atp files for the force field you're using. Then check the order and number of Na and Cl are correct.

Mark
_______________________________________________
gmx-users mailing list    gmx-users@gromacs.org
http://www.gromacs.org/mailman/listinfo/gmx-users
Please don't post (un)subscribe requests to the list. Use the www interface or send it to [EMAIL PROTECTED]
Can't post? Read http://www.gromacs.org/mailing_lists/users.php



_______________________________________________
gmx-users mailing list    gmx-users@gromacs.org
http://www.gromacs.org/mailman/listinfo/gmx-users
Please don't post (un)subscribe requests to the list. Use the www interface or send it to [EMAIL PROTECTED]
Can't post? Read http://www.gromacs.org/mailing_lists/users.php

Reply via email to