Hi,

First, it's just a warning that the force _might_ not be small enough since there's no bullet-proof way to say.

In general, both for final-stage energy minimization (with L-BFGS) and actual normal mode analysis you can use a setup with

double precision
switched coulomb & vdw interactions; cutoffs e.g. at 1.0 nm, switched from 0.8 nm (or shifted from 0 nm).
rlist at 1.2 to 1.3

It is imperative that you use the -t option to grompp when you create the NM run input file, so you read full precision binary coordinates and not the three-decimal gro file.

Cheers,

Erik