Carsten Baldauf wrote:
dear gromacs-users//
what would you think are good exchange rates between the replicas in a REMD?

:-) I'm about to submit a paper partly on this topic... the short answer is that most people publishing REMD exchange rates have one that is a good deal lower. There's literature that recommends 20%, but a lot of people are in the 10-30% range. If you get rates that seem too low, then the first thought is to decrease the period between exchange attempts in order to increase the exchange rate per unit simulation time, but there's published data (e.g. from Periole & Mark, J. Chem. Phys this year) that indicates that there are lower limits below which this is ineffective.

Mark
_______________________________________________
gmx-users mailing list    gmx-users@gromacs.org
http://www.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at http://www.gromacs.org/search before posting!
Please don't post (un)subscribe requests to the list. Use the www interface or send it to [EMAIL PROTECTED]
Can't post? Read http://www.gromacs.org/mailing_lists/users.php