Nicolas Schmidt wrote:
(a) Nope, my .mdp-file don't reads that. So I think I don't use one.
(b) I use some different software, that does exactly what I want. It's
very reliable and it's telling me that the pressure of a 2CLJ-fluid with
all the set parameters should be different. Since I wanna do the exact
same thing, the higher pressure kind of points out that in fact I'm not
doing the same.
(c) Exactly! Bondtype 5 doesen't imply a length parameter. So therefor
I'm using a constraint. David told me to do so. I'm really unsure at
this point, this is why I posted my issue.
Huh? Bond type 5 is only used for manipulating exclusion generation. You
seem to want a constrained bond, so you should either use one from 5.4
in your topology, or use the constraint algorithms on all bonds. Please
describe clearly both what you are doing, and what you are trying to do,
because at the moment I don't understand either of them!
Still: Though I thought I don't have to specify the
electrostatics-section since my molecule doesn't have any charges (or
does it???), what to do to totally switch the electrostatics off?
You should be reading section 7.3 of the manual closely and making these
choices actively, with reference to earlier in the manual where needed.
You'll need to understand well how both this other software and GROMACS
are doing the calculation in order to duplicate the ensemble averages.
Mark
_______________________________________________
gmx-users mailing list gmx-users@gromacs.org
http://www.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at http://www.gromacs.org/search before posting!
Please don't post (un)subscribe requests to the list. Use the
www interface or send it to [EMAIL PROTECTED]
Can't post? Read http://www.gromacs.org/mailing_lists/users.php