Berk

Thanks for the clarification.

I was aware of A-values copied to B-values, when no B-values in the FF exist, but actually this was new to me.

Regards

Maik Goette, Dipl. Biol.
Max Planck Institute for Biophysical Chemistry
Theoretical & computational biophysics department
Am Fassberg 11
37077 Goettingen
Germany
Tel.  : ++49 551 201 2310
Fax   : ++49 551 201 2302
Email : mgoette[at]mpi-bpc.mpg.de
        mgoette2[at]gwdg.de
WWW   : http://www.mpibpc.gwdg.de/groups/grubmueller/


Berk Hess wrote:
This behavior is itentional.
But it can indeed be confusing.
Therefore in Gromacs 4.0 a warning will be generated (and I have added
a table in the manual that explains all the possible combinations).

If you explicitly define parameters for the A-state, I don't see why
you would want the B-parameters to be looked up based on atom-type.
You would only want that when the A-state parameters are also determined
by the atom type.

Berk.


From: Maik Goette <[EMAIL PROTECTED]>
Reply-To: Discussion list for GROMACS users <gmx-users@gromacs.org>
To: GMX-mailinglist <gmx-users@gromacs.org>
Subject: [gmx-users] topology treatment in free energy calculations -possible bug
Date: Fri, 04 Jan 2008 15:15:57 +0100

Hi

I just found a strange behaviour of GROMACS, when processing topologies with B-values. Maybe I just think of it as unintuitive/bug, but here we go:

e.g. OPLS

Consider an angle given (all atoms have B-values, which angle-parameter can be found by GROMACS in the bonded.itp for the A- and B-state):

Original topology entry:
10    12    14     1

Manually edited entry (with the correct ff-term):
10    12    14     1     109.700     669.440

Now, a dump from the tpr-files yields the following:
Original:
functype[109]=ANGLES, thA= 1.09700e+02, ctA= 6.69440e+02, thB= 1.09500e+02, ctB= 2.92880e+02

Edited:
functype[109]=ANGLES, thA= 1.09700e+02, ctA= 6.69440e+02, thB= 1.09700e+02, ctB= 6.69440e+02

Now, what obviously happens is, that GROMACS searches the entries of the angle in the FF for both states and uses them in the case of the original topology. If one puts a manual entry into the topology for the A-state though, the B-state is simply copied, instead of searched by GROMACS.

This, IMHO, is quite inconvenient. Is this a bug or a feature?

Regards

--
Maik Goette, Dipl. Biol.
Max Planck Institute for Biophysical Chemistry
Theoretical & computational biophysics department
Am Fassberg 11
37077 Goettingen
Germany
Tel.  : ++49 551 201 2310
Fax   : ++49 551 201 2302
Email : mgoette[at]mpi-bpc.mpg.de
        mgoette2[at]gwdg.de
WWW   : http://www.mpibpc.gwdg.de/groups/grubmueller/
_______________________________________________
gmx-users mailing list    gmx-users@gromacs.org
http://www.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at http://www.gromacs.org/search before posting! Please don't post (un)subscribe requests to the list. Use the www interface or send it to [EMAIL PROTECTED]
Can't post? Read http://www.gromacs.org/mailing_lists/users.php

_________________________________________________________________
Live Search, for accurate results! http://www.live.nl

_______________________________________________
gmx-users mailing list    gmx-users@gromacs.org
http://www.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at http://www.gromacs.org/search before posting!
Please don't post (un)subscribe requests to the list. Use the www interface or send it to [EMAIL PROTECTED]
Can't post? Read http://www.gromacs.org/mailing_lists/users.php

.

_______________________________________________
gmx-users mailing list    gmx-users@gromacs.org
http://www.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at http://www.gromacs.org/search before posting!
Please don't post (un)subscribe requests to the list. Use the www interface or send it to [EMAIL PROTECTED]
Can't post? Read http://www.gromacs.org/mailing_lists/users.php

Reply via email to