Dear gmx users,

I am running a NPT simulation of Galactose in water for 10ns using united
atom force field on gromacs 3.3.1. The mdp parameters used are:
dt                      = 0.002
nstcomm                 = 1
nsteps                  = 5000000 ; 10 ns (run control)
nstxout                 = 10000
nstvout                 = 10000
nstxtcout               = 250
nstenergy               = 250
energygrps              = GLA   SOL
nstlist                 = 10
ns_type                 = grid
rlist                   = 1.1 ;(neighbor searching)
coulombtype             = PME
;rcoulomb_switch        = 1.0
rcoulomb                = 1.1
vdwtype                 = shift
;rvdw_switch            = 1.0
rvdw                    = 1.1
fourierspacing          = 0.12 ;(nm)
ewald_rtol              = 1e-5
pme_order               = 4  ;(electrostatics and VDW)
tcoupl                  = berendsen
tc_grps                 = GLA  SOL
tau_t                   = 0.1  0.1
ref_t                   = 300  300
pcoupl                  = berendsen
compressibility         = 4.5e-5
tau_p                   = 1.0
ref_p                   = 1
gen_vel                 = no
constraints             = all-bonds
constraint_algorithm    = lincs

After 10 ns i am calculating pressure using g_energy program. Average by
g_energy comes to be arround 0.99 bars while by xmgrace it comes to be 1.4
bars.
I reran the same simulation for 10ns using nstegergy = 1, instead of 250.
this time the average pressure calculated by g_energy and xmgrace was same
i.e. 0.99 bars.
This means that g_energy calculates average using all MD steps i.e. for
pressure values written after every 0.002 ps, while the average of xmgrace
 is from pressure values mentioned in .xvg file.
I converted .edr file to a text file, it contained three columns for each
term i.e. energy, av energy and sum energy. for eg :

  time:   5.00000e-01         step:           250
               Component        Energy    Av. Energy    Sum Energy
                G96Angle   2.30488e+01   7.26315e+03   5.68798e+03
             Proper Dih.   1.11964e+01   3.20236e+03   2.63734e+03
           Improper Dih.   4.14890e+00   2.55975e+03   1.09996e+03
                   LJ-14   2.02705e+01   3.40112e+03   4.57903e+03
              Coulomb-14   4.09736e+01   1.17554e+03   1.09782e+04
                 LJ (SR)   6.84730e+03   3.30860e+06   1.69561e+06
            Coulomb (SR)  -4.08518e+04   4.90539e+06  -1.02531e+07
            Coul. recip.  -2.35144e+03   2.94449e+04  -5.88310e+05
               Potential  -3.62563e+04   2.58237e+06  -9.12079e+06
             Kinetic En.   6.61766e+03   2.14269e+06   1.66692e+06
            Total Energy  -2.96387e+04   3.00496e+05  -7.45386e+06
             Temperature   2.98376e+02   4.35590e+03   7.51579e+04
          Pressure (bar)   5.51461e+02   1.30509e+07   6.42281e+04


My question is what these numbers mean and which of these columns are used
by g_energy program to calculate the average values (say average
pressure)??

Even if nstenergy = 250 and edr file has energies written after every 0.5
ps (250 steps), still g_energy calculates average pressure based on
pressure values writen after each MD step i.e. 0.002 ps. why is this so??

Thanxs in advance.

Rashmi




_______________________________________________
gmx-users mailing list    [email protected]
http://www.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at http://www.gromacs.org/search before posting!
Please don't post (un)subscribe requests to the list. Use the
www interface or send it to [email protected].
Can't post? Read http://www.gromacs.org/mailing_lists/users.php

Reply via email to