greetings GMX users, When I use genbox command for filling solvent in CGMD simulation with Gromacs suit, I must use a larger van der Waals distance to avoid crashes. when I use default value (0.105nm), system will crash. Which distance is suitable for performing CGMD simulation. I used 0.15 or 0.2nm as distances. Are those OK? I have to switch back to the smaller radius afterward, Is it correct? if yes, How can I do it? I tried with editconf but could not.
Best regards, Rasoul
-- gmx-users mailing list gmx-users@gromacs.org http://lists.gromacs.org/mailman/listinfo/gmx-users Please search the archive at http://www.gromacs.org/search before posting! Please don't post (un)subscribe requests to the list. Use the www interface or send it to gmx-users-requ...@gromacs.org. Can't post? Read http://www.gromacs.org/mailing_lists/users.php