----- Original Message -----
From: Kwee Hong <jestan1...@yahoo.com>
Date: Wednesday, July 7, 2010 11:36
Subject: [gmx-users] problem while simulating metal ions
To: gmx-users@gromacs.org


<!-- DIV {margin:0px;} 
-->-----------------------------------------------------------
| 


> 
> Hi.
> 
> I'm trying to subject a metalloprotein bound to cadmium to  a molecular 
> dynamics. I've defined the cadmium ion in the atom type  parameter file 
> (ffGa56a6.atp) and residue database (ffG53a6.rtp). And  the bond length and 
> bond  angle between the cadmium and sulphur of the metalloprotein had been  
> define in the force field file, too (ffG53a6abon.itp). As special bond  is 
> expected to be formed between the sulphur of cysteine and the cadmium  ions, 
> I've added the relevant information into specbond.dat.

You probably need a custom residue in your .rtp that will match 
cadmium+residue. Consider how the heme residue works and develop something 
analogous.
 
> But when I  run the pdb2gmx, there is no entries in the [ bonds ] and [ 
> angles ] for  those bond length and bond angle. And of course, as there is no 
> entries  in those parameter, there was no cadmium-thiolate bond observed when 
> I  visualised the structure using pymol. So, does that mean  that I would 
> need to  add them on manually? 

Yes, or get a working .rtp.

> To proceed with my simulation, I added the  values in [ bonds ] and [ angles 
> ] manually. And as I do not have the  relevant dihedral angle value from the 
> literature, I've deleted those  entries in my topology file and continue to 
> prepare and subject the  protein to energy minimization.

That just asks for problems later. There's a good reason why simulating 
metalloproteins is a difficult topic - among other issues, you have to develop 
suitable parameters.

> During EM, the potential energy of the  system started to remain constant at 
> step 124 and eventually steepest  descents converged to machine precision in 
> 128 steps with the maximum  force is on atom 279 which would be one of the 
> cadmium ions in the  system. When I visualised the system, one water molecule 
> was found to  attached with atom 279, so I deleted that water molecule and 
> subject the  system to em again. Yet the same thing occur after running for 
> 49  steps. What had gone wrong with my system? Is that cadmium molecule had  
> been running too far until it has gone out of the protein as water  molecule 
> are not suppose to come into the protein. 

It's impossible for us to guess what's wrong here, a) because it's hard to 
understand what you mean by a water molecule being "attached with atom 279", 
and b) because we don't know what you've done to your .top file contents. Look 
at your starting, progress, and end configurations and see what makes sense.

Mark |
-----------------------------------------------------------




-- 
gmx-users mailing list    gmx-users@gromacs.org
http://lists.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at http://www.gromacs.org/search before posting!
Please don't post (un)subscribe requests to the list. Use the 
www interface or send it to gmx-users-requ...@gromacs.org.
Can't post? Read http://www.gromacs.org/mailing_lists/users.php

Reply via email to