Sai Pooja wrote:
Hi,

I am aware there have been many threads on this topic and I have looked at some of them. I would still like to make this query. I am running an npt equilibration run for a solvated protein using Charmm27-Tip3p (nocmap). I ran the simulation for 1ns. The average values of pressure converge to 1.1 (ref=1.0), however, the fluctuations are not only large but range from -10^2 --- +10^2. I am pasting an excerpt from my log file here:


Seems perfectly normal to me.

http://www.gromacs.org/Documentation/Terminology/Pressure#Fluctuation

<snip>


Moreover, in this particular version of gromacs (git version, 20th June, 2010), RMS fluctuations are not reported in the log file.


This might be nice to restore, but you can still get all of that from g_energy.

-Justin

Pooja




--
Quaerendo Invenietis-Seek and you shall discover.


--
========================================

Justin A. Lemkul
Ph.D. Candidate
ICTAS Doctoral Scholar
MILES-IGERT Trainee
Department of Biochemistry
Virginia Tech
Blacksburg, VA
jalemkul[at]vt.edu | (540) 231-9080
http://www.bevanlab.biochem.vt.edu/Pages/Personal/justin

========================================
--
gmx-users mailing list    gmx-users@gromacs.org
http://lists.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at http://www.gromacs.org/search before posting!
Please don't post (un)subscribe requests to the list. Use the www interface or send it to gmx-users-requ...@gromacs.org.
Can't post? Read http://www.gromacs.org/mailing_lists/users.php

Reply via email to