Dear gmxusers,

 

I have a question here concerning nstcomm.

 

I got the note below after doing grompp, I'd like to do something about
it.

NOTE 1 [file HW_NPT.mdp]:

  nstcomm < nstcalcenergy defeats the purpose of nstcalcenergy, setting

  nstcomm to nstcalcenergy

 

Currently, my nstcomm is set at 1 while nstlist at 10 (default
nstcalcenergy, nsttcouple, nstpcouple = -1). I would like to know, if I
set nstcomm to 10, therefore removing the center of mass motion every 10
steps instead of every step, will it adversely affect my simulation
(because the center of mass is allowed to move in between the 10-step
interval)?

 

I notice the default value for nstcomm is actually 10, so I gather
setting it to 10 should be OK?  Thank you.

 

HW

 

<< This message and any attachment are intended solely for the addressee and 
may contain confidential information. If you have received this message in 
error, please send it back to me, and immediately delete it. Please do not use, 
copy or disclose the information contained in this message or in any 
attachment. Any views or opinions expressed by the author of this email do not 
necessarily reflect the views of the University of Nottingham. 

This message has been checked for viruses but the contents of an attachment may 
still contain software viruses which could damage your computer system: you are 
advised to perform your own checks. Email communications with the University of 
Nottingham may be monitored as permitted by UK & Malaysia legislation. >>
-- 
gmx-users mailing list    gmx-users@gromacs.org
http://lists.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/Search before posting!
Please don't post (un)subscribe requests to the list. Use the 
www interface or send it to gmx-users-requ...@gromacs.org.
Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

Reply via email to