Hi all,

I am trying to investigate how the slab geometry correction affects
calculated Coulomb energies for interface systems. I have an air/water
interface with a box size of 3x3x9 nm. I ran 2 independent simulations with
changing ewald_geometry option: 3d (default value), and 3dc. You can find
short and reciprocal Coulomb  energies below:

                                      *3d                     3dc *
short-range Coulomb -45260.2 (6.5)       -45258.4 (5)
Reciprocal Coulomb  -3325.72 (0.13)     -3325.54 (0.1)

I am wondering why short-range and reciprocal Coulomb energies are the same
within the error bars even though I use different schemes for
ewald_geometry?

Regards

-- 
----------------------------------------------------------------------------
Ozge Engin- PhD candidate
Koc University, College of Engineering
Dept. of Computational Sciences & Engineering
Rumelifeneri Yolu, 34450 Sariyer/Istanbul, Turkey
Email: ozge.en...@gmail.com, ozen...@ku.edu.tr
Phone:+90-212-338-1542
Fax:  +90-212-338-1548
-- 
gmx-users mailing list    gmx-users@gromacs.org
http://lists.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/Search before posting!
Please don't post (un)subscribe requests to the list. Use the 
www interface or send it to gmx-users-requ...@gromacs.org.
Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

Reply via email to