On 25/11/2011 6:38 PM, James Starlight wrote:
Mark, Tsjerk thanks!

I've check my uncompleated produced MD run by G_energy and find that average pressure is 1.1 Bar that is most close to ref.


By the way could you tell me about extra possible ways of checking running simmulation? ( E.g I'm calculating long produce trajectory and want to check my uncompleated system ).

As I understood One of the possible way is the ussage of G_energy but how I could obtain GRO and TPR file from uncompleated MD trajectory ( .trr) (recently I've asked about this but I've missed that topic ;o) ?

Choose a length of time in advance that you are happy to risk being wasted. Run that length of time, make a backup, check whatever you want to check, then continue the simulation. As you acquire confidence, you will want to increase that time (and like everyone you will regret that decision at least once!)

Mark




Thanks again

James

2011/11/25 Tsjerk Wassenaar <tsje...@gmail.com <mailto:tsje...@gmail.com>>

    Hi James,

    There have been extensive discussions about this on the list.
    Check the archives. In short, smaller systems give larger
    fluctuations, and shorter simulations give larger deviations from
    the expected average.

    Cheers,

    Tsjerk

    On Nov 25, 2011 7:23 AM, "James Starlight"
    <jmsstarli...@gmail.com <mailto:jmsstarli...@gmail.com>> wrote:

    Dear Gromacs Users!


    At the present time I'm simulating small peptide (11 a.c in
    coiled conformation) in water.

    I've desided to use parameters from Lysozyme simmulation ( opls
    ff for parametrisation and all mdp parameters from that simulation).

    Because my peptide was smaller than typical globular protein I've
    desided to use bigger periodical box than in tutorial

    I've used editconf  -c -d 1.5 -bt cubic instead of 1.0 nm in
    tutorial wich resulted in bigger box relative peptide size.

    so i have this box vectors    5.39318   5.39318   5.39318

    My experiment was in full agreement with the above tutorial until
    NVP phase was conducted. I have conducted 100ps equilibration but
    When I've checked average pressure it was 0.75 atm instead of 1
    BAR and have big RMSD- 200. (also I've checked my system visually
    but it looks fine- I have not  pointed any artifacts linked with
    unstable pressure like voids in the solvent etc). Should I
    equilibrate my sustem longer until pressure would not be
    stabilized to reference BAR?  What another options should i take
    into account during simulation of the small peptides ?

    Thanks,

    James

    --
    gmx-users mailing list gmx-users@gromacs.org
    <mailto:gmx-users@gromacs.org>
    http://lists.gromacs.org/mailman/listinfo/gmx-users
    Please search the archive at
    http://www.gromacs.org/Support/Mailing_Lists/Search before posting!
    Please don't post (un)subscribe requests to the list. Use the
    www interface or send it to gmx-users-requ...@gromacs.org
    <mailto:gmx-users-requ...@gromacs.org>.
    Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

    --
    gmx-users mailing list gmx-users@gromacs.org
    <mailto:gmx-users@gromacs.org>
    http://lists.gromacs.org/mailman/listinfo/gmx-users
    Please search the archive at
    http://www.gromacs.org/Support/Mailing_Lists/Search before posting!
    Please don't post (un)subscribe requests to the list. Use the
    www interface or send it to gmx-users-requ...@gromacs.org
    <mailto:gmx-users-requ...@gromacs.org>.
    Can't post? Read http://www.gromacs.org/Support/Mailing_Lists





-- 
gmx-users mailing list    gmx-users@gromacs.org
http://lists.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/Search before posting!
Please don't post (un)subscribe requests to the list. Use the 
www interface or send it to gmx-users-requ...@gromacs.org.
Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

Reply via email to