On 2011-11-27 12:15, Igor Druz wrote:
write to gro in angstroms, read from gro in angstroms, convert into nm
in grompp.

once more you don't have to use gro, use g96 if precision is important. if we'd introduce a gro format in angstrom it couldn't be called .gro anyway since that would confuse tons of programs using it.


On Sun, Nov 27, 2011 at 10:41 AM, Tsjerk Wassenaar <tsje...@gmail.com
<mailto:tsje...@gmail.com>> wrote:

    Hi Igor,

    Please do read the manual. The GRO file format is a fixed-width format
    with %8.3f for coordinates, velocities and forces. Changing the format
    to %9.4f will break everything written in fortran. And, yes, people
    still use fortran. So which point did I miss? :)

    Cheers,

    Tsjerk


    On Sun, Nov 27, 2011 at 11:38 AM, Igor Druz <idruz...@gmail.com
    <mailto:idruz...@gmail.com>> wrote:
     > You are missing the point. Quoting my response to David:
     >
     > I appreciate the history of the matter, but it would save a lot
    of headache
     > to store coordinates in angstroms in gro files, i.e., not to omit
    "2" in
     > 4.172 A in the pdb file by converting it to 0.417 nm in the gro
    file. What
     > is the point in dropping useful "2" by introducing useless "0"?
     >
     > On Sun, Nov 27, 2011 at 10:30 AM, Tsjerk Wassenaar
    <tsje...@gmail.com <mailto:tsje...@gmail.com>>
     > wrote:
     >>
     >> My my. Why is it a fault to adhere to ISO units (nm) over
    non-standard
     >> (A)? It's a choice, but a choice is not faulty. The consequences may
     >> be undesirable. But shouldn't a user, certainly a computation
     >> scientist, understand the file formats, as an experimentalist should
     >> know its solvent? And know the consequences of using one over
    another?
     >> Mark is correct to state that a picometer uncertainty at the
    start has
     >> no consequences for molecular dynamics simulations. For single point
     >> eneriges they will have. But no one ever forced anyone to use GRO
     >> rather than PDB format. That's the choice the researcher makes. And,
     >> at least in my tutorial, that difference between GRO and PDB
    format is
     >> stressed. The choice to use standard units is historical, and lies
     >> decades back in time. Could we now change it to A, because a
    'faulty'
     >> choice was made?
     >>
     >> I'm terribly sorry that you need to do a lot of work again,
    Igor. But
     >> you can't shove the blame in another's shoes. You overlooked
     >> something, lead by presumptions about standardization in units and
     >> file formats. May I wonder why you only found out now, after all the
     >> work has been done? This difference would have showed up with the
     >> first test, right? But again, it's not us against you, and I'm sorry
     >> you have to go through this. Trust me, most of us have had such
     >> moments, although with a different aspect.
     >>
     >> Best,
     >>
     >> Tsjerk
     >>
     >> On Sun, Nov 27, 2011 at 11:03 AM, Igor Druz <idruz...@gmail.com
    <mailto:idruz...@gmail.com>> wrote:
     >> > You can put whichever spin you like into what is said,
    but there is a
     >> > clear
     >> > (and unnecessary) fault with the way coordinates are stored in
    gro files
     >> > when made from pdb using pdb2gmx.
     >> >
     >> > On Sun, Nov 27, 2011 at 12:39 AM, Mark Abraham
    <mark.abra...@anu.edu.au <mailto:mark.abra...@anu.edu.au>>
     >> > wrote:
     >> >>
     >> >> On 27/11/2011 5:07 AM, Igor Druz wrote:
     >> >>
     >> >> On Sat, Nov 26, 2011 at 5:35 PM, <chris.ne...@utoronto.ca
    <mailto:chris.ne...@utoronto.ca>> wrote
     >> >>>
     >> >>> 1. why repeat the calculations? If you're talking about
    simulations
     >> >>> then
     >> >>> there is no need to repeat them due to this. You will get
    different
     >> >>> answers
     >> >>> with the same starting coordinates if you simply change the
    initial
     >> >>> velocities. If you're talking about instantaneous energy
    calculations
     >> >>> then I
     >> >>> suppose you might need to redo it, but they should be very
    quick,
     >> >>> right?
     >> >>>
     >> >>
     >> >> The calculations must be repeated. You are making irrelevant
     >> >> assumptions
     >> >> without knowing what the calculations are for.
     >> >>
     >> >> You asserted that there should have been a warning without
    explaining
     >> >> why
     >> >> this loss of precision was material. Chris knew that many uses of
     >> >> pdb2gmx
     >> >> change the atomic configuration considerably, e.g. new hydrogen
     >> >> positions,
     >> >> building termini, etc. so that any change of precision of
    coordinates
     >> >> is not
     >> >> a big deal, and even less important once a simulation has run
     >> >> afterwards. If
     >> >> you want to engage in constructive dialogue, please explain
    why the
     >> >> loss of
     >> >> precision was material, in order to clarify the reason for
    your request
     >> >> for
     >> >> a warning message. If you wish to blow off steam, please do it
     >> >> elsewhere.
     >> >>
     >> >>
     >> >>>
     >> >>> 2. The .gro files do not carry useless zeroes. you have it
     >> >>> backwards...
     >> >>> the gro files end up with fewer digits.
     >> >>>
     >> >>
     >> >> 0.417 or 4.172. Shall I continue? I know which one I prefer.
     >> >>
     >> >>>
     >> >>> 3. it's a little annoying to find out that you already knew the
     >> >>> answer.
     >> >>> Why not state that at the outset? Unless I misunderstand
    this point,
     >> >>> this
     >> >>> will mark the end of my comments since holding back
    information on
     >> >>> purpose
     >> >>> just wastes people's time.
     >> >>>
     >> >>
     >> >> Check my 1st e-mail, please. It is NOT asking for
    clarification. It is
     >> >> requesting an explicit warning message.
     >> >>
     >> >> There's nothing to warn about. You thought that "switching from
     >> >> Angstrom
     >> >> to nanometers" was significant somehow, and then assumed that
    different
     >> >> file
     >> >> formats would definitely contain identical information, and
    didn't
     >> >> check
     >> >> their contents.
     >> >>
     >> >> Mark
     >> >>
     >> >>
     >> >>>
     >> >>> Chris.
     >> >>>
     >> >>> -- original message --
     >> >>>
     >> >>> I already knew the reason. But I had to find this out hard
    way. Now
     >> >>> facing
     >> >>> a dreading prospect of repeating tons of calculations!
      Hence the
     >> >>> request
     >> >>> for the "bad for the health" sign. Btw, gromacs issues a lot of
     >> >>> warnings,
     >> >>> but not this one :D
     >> >>>
     >> >>> What a bright idea to switch from angstroms to nanometers!
    Now the gro
     >> >>> files carry a lot of useless zeros.
     >> >>>
     >> >>>
     >> >>> --
     >> >>> gmx-users mailing list gmx-users@gromacs.org
    <mailto:gmx-users@gromacs.org>
     >> >>> http://lists.gromacs.org/mailman/listinfo/gmx-users
     >> >>> Please search the archive at
     >> >>> http://www.gromacs.org/Support/Mailing_Lists/Search before
    posting!
     >> >>> Please don't post (un)subscribe requests to the list. Use thewww
     >> >>> interface or send it to gmx-users-requ...@gromacs.org
    <mailto:gmx-users-requ...@gromacs.org>.
     >> >>> Can't post? Read http://www.gromacs.org/Support/Mailing_Lists
     >> >>
     >> >>
     >> >>
     >> >>
     >> >>
     >> >> --
     >> >> gmx-users mailing list gmx-users@gromacs.org
    <mailto:gmx-users@gromacs.org>
     >> >> http://lists.gromacs.org/mailman/listinfo/gmx-users
     >> >> Please search the archive at
     >> >> http://www.gromacs.org/Support/Mailing_Lists/Search before
    posting!
     >> >> Please don't post (un)subscribe requests to the list. Use the
     >> >> www interface or send it to gmx-users-requ...@gromacs.org
    <mailto:gmx-users-requ...@gromacs.org>.
     >> >> Can't post? Read http://www.gromacs.org/Support/Mailing_Lists
     >> >
     >> >
     >> > --
     >> > gmx-users mailing list gmx-users@gromacs.org
    <mailto:gmx-users@gromacs.org>
     >> > http://lists.gromacs.org/mailman/listinfo/gmx-users
     >> > Please search the archive at
     >> > http://www.gromacs.org/Support/Mailing_Lists/Search before
    posting!
     >> > Please don't post (un)subscribe requests to the list. Use the
     >> > www interface or send it to gmx-users-requ...@gromacs.org
    <mailto:gmx-users-requ...@gromacs.org>.
     >> > Can't post? Read http://www.gromacs.org/Support/Mailing_Lists
     >> >
     >>
     >>
     >>
     >> --
     >> Tsjerk A. Wassenaar, Ph.D.
     >>
     >> post-doctoral researcher
     >> Molecular Dynamics Group
     >> * Groningen Institute for Biomolecular Research and Biotechnology
     >> * Zernike Institute for Advanced Materials
     >> University of Groningen
     >> The Netherlands
     >> --
     >> gmx-users mailing list gmx-users@gromacs.org
    <mailto:gmx-users@gromacs.org>
     >> http://lists.gromacs.org/mailman/listinfo/gmx-users
     >> Please search the archive at
     >> http://www.gromacs.org/Support/Mailing_Lists/Search before posting!
     >> Please don't post (un)subscribe requests to the list. Use the
     >> www interface or send it to gmx-users-requ...@gromacs.org
    <mailto:gmx-users-requ...@gromacs.org>.
     >> Can't post? Read http://www.gromacs.org/Support/Mailing_Lists
     >
     >
     > --
     > gmx-users mailing list gmx-users@gromacs.org
    <mailto:gmx-users@gromacs.org>
     > http://lists.gromacs.org/mailman/listinfo/gmx-users
     > Please search the archive at
     > http://www.gromacs.org/Support/Mailing_Lists/Search before posting!
     > Please don't post (un)subscribe requests to the list. Use the
     > www interface or send it to gmx-users-requ...@gromacs.org
    <mailto:gmx-users-requ...@gromacs.org>.
     > Can't post? Read http://www.gromacs.org/Support/Mailing_Lists
     >



    --
    Tsjerk A. Wassenaar, Ph.D.

    post-doctoral researcher
    Molecular Dynamics Group
    * Groningen Institute for Biomolecular Research and Biotechnology
    * Zernike Institute for Advanced Materials
    University of Groningen
    The Netherlands
    --
    gmx-users mailing list gmx-users@gromacs.org
    <mailto:gmx-users@gromacs.org>
    http://lists.gromacs.org/mailman/listinfo/gmx-users
    Please search the archive at
    http://www.gromacs.org/Support/Mailing_Lists/Search before posting!
    Please don't post (un)subscribe requests to the list. Use the
    www interface or send it to gmx-users-requ...@gromacs.org
    <mailto:gmx-users-requ...@gromacs.org>.
    Can't post? Read http://www.gromacs.org/Support/Mailing_Lists






--
David van der Spoel, Ph.D., Professor of Biology
Dept. of Cell & Molec. Biol., Uppsala University.
Box 596, 75124 Uppsala, Sweden. Phone:  +46184714205.
sp...@xray.bmc.uu.se    http://folding.bmc.uu.se
--
gmx-users mailing list    gmx-users@gromacs.org
http://lists.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/Search before posting!
Please don't post (un)subscribe requests to the list. Use the www interface or send it to gmx-users-requ...@gromacs.org.
Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

Reply via email to