On 26/02/2012 3:58 PM, dina dusti wrote:
Dear Gromacs Specialists,

My total time for simulation is 600000 ps (600 ns) because I work with MARTINI coarse-grained force field and this time is enough for my system,

Different observables converge over different time scales. The autocorrelation time of potential energy in a fine-grained force field is around 1ps, but that of the kinetic energy is very much shorter. Atomic positions normally much longer.

but when I do g_analyze -ee, I take this warning:

Warning: tau2 is longer than the length of the data (864000)
the statistics might be bad

Should I increase the total time of simulation but this time is enough?!

We don't have any information with which to judge - and ultimately you will need to make this decision yourself.

Mark
-- 