Hi all,

I am experiencing a potential problem with my PMF curve not starting
at position 0 of the reaction coordinate, which is defined by a path
starting from 0.0 nm and ending at 0.5 nm.  When I run the GROMACS
g_wham analysis at Umb. Pos 0.0 (see below), to say, 0.02 nm, the PMF
curve doesn't start out at 0.0 nm but gets offset to ~0.01 nm in the
resulting figure.  Its corresponding histogram also gets offset by the
same amount.  This is particularly peculiar to me because my frame1
*is* the structure at 0.0nm of the S path.  I also double-checked my
COLVAR file and there are no negative values in my COLVAR file:

# UMBRELLA    3.0
# Compnent selection: 0 0 1
# nSkip 1
# Ref. Group 'TestAtom'
# Nr. of pull groups 1
# Group 1 'GR1' Umb. Pos. 0.0 Umb. Cons. 50000
#####
0.0300  0.000047500
0.0400  0.000103337
0.0500  0.000163820
0.0600  0.000265547
0.0700  0.000408777
0.0800  0.000550200
0.0900  0.000653522

Has anyone else experienced this problem before?  I'm hoping it's just
some minor issue in g_wham.  I even invoked the -zprof0 flag to "-
zprof 0" and it did not set my PMF curve to start at 0.

Sincerely,
Lili
-- 
gmx-users mailing list    gmx-users@gromacs.org
http://lists.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/Search before posting!
Please don't post (un)subscribe requests to the list. Use the 
www interface or send it to gmx-users-requ...@gromacs.org.
Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

Reply via email to