Hi

You said:

>The blank lines will be filled in with existing parameters from [angletypes] 
>in ffbonded.itp.
I let the lines empty and I got an error at the first grompp, before energy 
minimization. grompp missed this empty lines. Here a part out of the errors:

ERROR 28 [file topol.top, line 229]:
  No default Angle types


ERROR 29 [file topol.top, line 233]:
  No default Improper Dih. types

My system is a cofactor, the force field is CHARMM27, parametrized with data 
out of a supporting information of a group that determined this parameters for 
my cofactor by experiments and quantum mechanical calculations. In 
residuetypes.dat I defined ISO Isoalloxazin. In the force field order I gave 
all informations (I guess).

What could be the problem?

I am able to complete the topol.top file by hand, but I really like to know 
what is the problem here. 


Thanks for help

Greetings
Lara





----- Ursprüngliche Message -----
Von: Justin A. Lemkul <jalem...@vt.edu>
An: Discussion list for GROMACS users <gmx-users@gromacs.org>
CC: 
Gesendet: 20:34 Dienstag, 6.März 2012
Betreff: Re: [gmx-users] Missing Interactions in [ angles ] Section in Topology



Lara Bunte wrote:
> Hi
> 
> In some lines the equilibrium angle and the force constant is missing.I give 
> you an example:
> 
> 
> The [ angles ] section is build like
> 
> [ angles ]
> ;  ai    aj    ak funct            c0            c1            c2            
> c3
>    2     1    19     1    123.75     250.00
>     1     2    3      1    123.75     250.00
>     1     2    4      1    117.47     230.00
> 
> 
> 
> And my pdb2gmx output is for example something like
> 
> [ angles ]
> ;  ai    aj    ak funct            c0            c1            c2            
> c3
>     2     1    19     1    123.75     250.00
>     1     2     3      1  
>     1     2     4      1    117.47     230.00
> 
> 

So you have a complete topology and one that has missing parameters, or are you 
adapting an incomplete topology?

What force field are you using?  What is the system?  For a normal protein 
system, most force fields (all except Gromos, if I recall) produce bonded 
directives with no parameters; they are looked up from ffbonded.itp and not 
stated explicitly, so "missing" parameters are completely normal and not 
problematic.  If you're dealing with something nonstandard and you've had to 
create .rtp entries, you'll need to post that information for diagnostic 
purposes.

In principle, there's nothing wrong with any of this.  The blank lines will be 
filled in with existing parameters from [angletypes] in ffbonded.itp.  These 
parameters are only overwritten if explicitly present in the topology.  If 
there is a bonded interaction referenced in the topology that does not exist in 
ffbonded.itp, grompp will fail with a fatal error.

-Justin

-- ========================================

Justin A. Lemkul
Ph.D. Candidate
ICTAS Doctoral Scholar
MILES-IGERT Trainee
Department of Biochemistry
Virginia Tech
Blacksburg, VA
jalemkul[at]vt.edu | (540) 231-9080
http://www.bevanlab.biochem.vt.edu/Pages/Personal/justin

========================================
-- gmx-users mailing list    gmx-users@gromacs.org
http://lists.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/Search before posting!
Please don't post (un)subscribe requests to the list. Use the www interface or 
send it to gmx-users-requ...@gromacs.org.
Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

--
gmx-users mailing list    gmx-users@gromacs.org
http://lists.gromacs.org/mailman/listinfo/gmx-users