On 12/06/2012 9:14 PM, rama david wrote:


On Tue, Jun 12, 2012 at 4:40 PM, rama david <ramadavidgr...@gmail.com <mailto:ramadavidgr...@gmail.com>> wrote:


    Hi Gromacs Friends,

    I did NPT for 100 ps with folowing parameter

    ; Temperature coupling is on
    tcoupl        = V-rescale    ; modified Berendsen thermostat
    tc-grps        = Protein Non-Protein    ; two coupling groups -
    more accurate
    tau_t        = 0.1    0.1    ; time constant, in ps
    ref_t        = 310     310    ; reference temperature, one for
    each group, in K
    ; Pressure coupling is on
    pcoupl        = Parrinello-Rahman    ; Pressure coupling on in NPT
    pcoupltype    = isotropic    ; uniform scaling of box vectors
    tau_p        = 2.0        ; time constant, in ps
    ref_p        = 1.0        ; reference pressure, in bar


    I got foolowing result by using g_energy

    Energy                      Average   Err.Est.       RMSD  Tot-Drift
    
-------------------------------------------------------------------------------
Pressure -3.99675 0.66 518.604 -2.89716 (bar)


    Is it is right??
    Is the system is equilibrated or I need to give more time ?????

 I am worried because of avg is -ve ...

The sign reflects the tendency of the system to expand or contract. No big deal. Also, as Justin said, this value is not significantly different from your reference value. See http://www.gromacs.org/Documentation/Terminology/Pressure

Mark
-- 
gmx-users mailing list    gmx-users@gromacs.org
http://lists.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/Search before posting!
Please don't post (un)subscribe requests to the list. Use the 
www interface or send it to gmx-users-requ...@gromacs.org.
Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

Reply via email to