Dear justin,
                 Thank you For your Previous reply
I  am doing Lipid -protein  Bilayer simulation.  As instructed in your tutorial 
i Have done Shrinking And  EM .until i have Attained Area per Lipid 62.36A. 
Then I Have solvated  as in the Tutorial (  using Vadradii 0.375)  using Genbox 
tool 

As result My system has Solvated with 74496 Solvent Molecules . This is Too 
Higher for My system 

Is there is any  Gromacs tools or other server or Package  Available to delete  
Excess Water molecules . I wanted to Keep Water Molecules only on Either side 
of Bilayer  While  I need to Delete  Water Molecules Nearer to Protein  and 
deep inside the box ( box size 6 6 6) 


When i Try to solvate With Lower Number of Molecules ( 2000 Molcules) Which 
need to be Kept On either side of Bilayer ,  

Then I need to Continue Shrinking process There by It is  getting Over 
compressed  ( Area Per Lipid Become Less than Experimental Value) 

Also When I solvate with Experimental APL 62A Then My system become over 
solvated ? How to rectify this Problem 


I Need to attain Both Correct APL and Solvated with Least  Number of Molecules 
Only On either side of  Lipid Bilayer   

Thanks In Advance
--
gmx-users mailing list    gmx-users@gromacs.org
http://lists.gromacs.org/mailman/listinfo/gmx-users
* Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/Search before posting!
* Please don't post (un)subscribe requests to the list. Use the
www interface or send it to gmx-users-requ...@gromacs.org.
* Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

Reply via email to