On 4/16/13 1:13 PM, Albert wrote:
Hi Justin:

  thanks for kind reply.
  Yes, there many atom clashes in CHARMM-GUI system, so I add very strong force
on protein and ligands, and try to minimize the rest of the system....

do you have any idea how can I solve the issue and make it work?


Create a more physically reasonable starting structure.

-Justin

--
========================================