On 10/31/13 8:25 AM, Riccardo Concu wrote:
Dear all, I'm having some problems during the cool-down process after
the NVT.
I'm running the NVT process at a T of 500K for 3ns and everything is
going well but when I cool down the system blows up. I am running the
cool down for 100ps, I tried to run the process for longer time (500 ps)
and decrease nstlist option up to 5 but it seems it doesn't work. The EM
seems to be fine with very low forces:
Potential Energy  = -3.1736706e+05
Maximum force     =  2.6573439e+01 on atom 105
Norm of force     =  3.1027287e-01

The NVT is compiled with the following mdp:
define      = -DPOSRES  ; position restrain the protein and ligand
; Run parameters
integrator  = md        ; leap-frog integrator
nsteps      = 1500000     ; 2 * 50000 = 100 ps
dt          = 0.002     ; 2 fs
; Output control
nstxout     = 10000       ; save coordinates every 0.2 ps
nstvout     = 10000       ; save velocities every 0.2 ps
nstenergy   = 10000       ; save energies every 0.2 ps
nstlog      = 10000       ; update log file every 0.2 ps
energygrps  = NAP NA WAT MET SI3 SI- I LI+ LI-
; Bond parameters
continuation    = no            ; first dynamics run
constraint_algorithm = lincs    ; holonomic constraints
constraints     = all-bonds     ; all bonds (even heavy atom-H bonds)
constrained
lincs_iter      = 1             ; accuracy of LINCS
lincs_order     = 4             ; also related to accuracy
; Neighborsearching
vdwtype = cutoff
ns_type     = grid      ; search neighboring grid cells
nstlist     = 20         ; 10 fs
rlist       = 1.0       ; short-range neighborlist cutoff (in nm)
rcoulomb    = 1.0       ; short-range electrostatic cutoff (in nm)
rvdw        = 1.0       ; short-range van der Waals cutoff (in nm)
; Electrostatics
coulombtype     = PME       ; Particle Mesh Ewald for long-range
electrostatics
pme_order       = 4         ; cubic interpolation
fourierspacing  = 0.16      ; grid spacing for FFT
; Temperature coupling
tcoupl      = V-rescale                     ; modified Berendsen
thermostat
tc-grps     = NAP NA WAT MET SI3 SI- I LI+ LI-          ; two coupling
groups - more accurate

Frankly, I'm amazed this was stable. I can't imagine that any system justifies this many individual thermostats.

<snip>

Pcoupl                   = Parrinello-Rahman

I doubt that you want to try to use Parrinello-Rahman while simultaneously decreasing the temperature. Even for equilibration runs at stable temperature, P-R is a poor choice. I would suggest trying your cooling under NVT, or if you absolutely need to do it under NPT, use Berendsen instead; it is much more forgiving.

-Justin

--
==================================================

Justin A. Lemkul, Ph.D.
Postdoctoral Fellow

Department of Pharmaceutical Sciences
School of Pharmacy
Health Sciences Facility II, Room 601
University of Maryland, Baltimore
20 Penn St.
Baltimore, MD 21201

jalem...@outerbanks.umaryland.edu | (410) 706-7441

==================================================
--
gmx-users mailing list    gmx-users@gromacs.org
http://lists.gromacs.org/mailman/listinfo/gmx-users
* Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/Search before posting!
* Please don't post (un)subscribe requests to the list. Use the www interface or send it to gmx-users-requ...@gromacs.org.
* Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

Reply via email to